Kidney Transplant Research - Risks, Prognosis, Procedure, Surgery, Organ Donation

Kidney Transplant Research Today is a free monthly online journal that collates and summarizes the latest research about Kidney Transplant, including details on risks, prognosis, procedure, surgery, organ donation.


Kidney Transplant Research Today

Home

View Latest Issue

Information About Kidney Transplant

Books on Kidney Transplant

Advertising in Research Today

View Other Research Today Publications



Detection of early renal transplant rejection by minimally-invasive monitoring of impedance variability.

Parsonnet V, Marak MJ, Panken E, Zucker MJ, Villanueva A, Kucher T, Driller J, Tuder G, Olesnicky L, Combs W

Division of Surgical Research, Newark Beth Israel Medical Center, Newark, NJ 07112, USA. vpace1@earthlink.net <vpace1@earthlink.net>

BACKGROUND: Allograft rejection that occurs after renal transplants is identified by surveillance biopsies or by abnormal laboratory and/or hemodynamic data. The latter are insensitive markers of rejection that may not appear until significant histologic damage has already occurred. Therefore, a sensitive and specific non-invasive method of detecting early rejection of transplanted solid organs is needed. METHOD: A single canine renal allograft was implanted followed by bilateral nephrectomy. Bipolar pacing electrodes were implanted at each end of the transplanted kidney. A second set of electrodes was implanted in the liver, which served as a non-rejecting normal organ. Electrodes were connected to an implantable sensor placed in the subcutaneous tissue. Electrical tissue impedance levels were telemetrically downloaded daily. The clinical status of the transplanted organ was monitored by following the blood urea nitrogen and serum creatinine levels, urine output, and clinical appearance. After tissue impedance levels had stabilized, all immunosuppressants were abruptly discontinued. Clinical signs of rejection were then observed after a few days. RESULTS: Rejection was accompanied by changes in electrical impedance of the implanted organ. These changes, when observed, occurred 1-5 days before clinical signs of rejection appeared. CONCLUSION: Analyses of these data suggest that development of a minimally-invasive high-confidence sensor of early rejection of solid organ transplants is feasible.

Published 2 April 2007 in Biosens Bioelectron, 22(11): 2749-53.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2004-2008 Kidney Transplant Research Today. All Rights Reserved.



Kidney Transplant Research Today Archive:

Volume 1 (2004)
  Issue 1 (December)

Volume 2 (2005)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 5 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)



Kidney Transplant Books

Ethics and the Kidney

Ethics and the Kidney